Synaccess PDU Series Breakdown

Synaccess offers a wide range of intelligent PDU series designed to match your technical requirements and budget—whether you need basic control or advanced enterprise features. With flexible options across form factors, outlet configurations, and management capabilities, there's a Synaccess PDU to fit every application.

Form Factor and General Info

SynLink SP
netBooter DX
netBooter DU
netBooter B
Series Description
Next-gen PDUs with advanced capabilities and custom feature support.
Intelligent switched PDUs with modern protocols and integration support.
Basic networked, switched PDU with HTTPS support
Basic networked, switched PDUs for straightforward control.
Platform
Arm Cortex A5
Arm Cortex A5
Rabbit
Rabbit
Outlet and Form Factor Options
4 Outlets (Compact)
8 Outlets (1U)
16 Outlets (2U)
24 Outlets (0U)
36 Outlet (0U)
2 Outlets (Compact)
5 Outlets (Strip)
8 Outlets (1U)**
**coming soon
2 Outlets (Compact)
5 Outlets (Strip)
8 Outlets (1U)
16 Outlets (2U)
10 Outlets (0U)
20 Outlets (0U)
2 Outlets (Compact)
5 Outlets (Strip)
Independent Outlet Control
Yes
Yes
Yes
Yes
Relay Outputs
(Switch External Signals)
Yes, Compact PDU Only
No
No
No
Ethernet Ports
10/100MBps RJ45
Optional 2nd 10/100Mbps via USB
Optional WiFi

10/100MBps RJ45
10/100MBps RJ45
10Mbps RJ45
10BaseT Half-Duplex
Local Serial Ports
USB and RJ45
USB or DB9
USB or DB9
USB or DB9
Sensor Ports
2 Sensor Ports
1 Sensor Port
1 Sensor Port
No
Front Panel
Full Color LCD Display
Multi-Function User Buttons
7-Seg or LCD Display
Outlet State LEDs
Manual Outlet Control Button
7-Seg or LCD Display
Outlet State LEDs
Manual Outlet Control Button
No Display
Outlet State LEDs
Manual Outlet Control Button
Certifications
UL 62368-1
UL 62368-1
UL 62368-1
UL 62368-1
Warranty
3 Years (Parts + Labor)
3 Years (Parts + Labor)
2 Years (Parts + Labor)
2 Years (Parts + Labor)

Power

SynLink SP
netBooter DX
netBooter DU
netBooter B
Input Voltage
120V, 208V, 230V, 240V, 415V
120V, 208V, 230V, 240V
120V, 208V, 230V, 240V
120V, 208V, 230V, 240V
Input Plugs/Receptables
IEC320-C14
IEC320-C20
NEMA L5-20P Attached Cord
NEMA L5-30P Attached Cord
NEMA L6-30P Attached Cord

More custom options available
IEC320-C14
IEC320-C20
IEC320-C14
IEC320-C20
NEMA L5-20P Attached Cord
IEC320-C14
Output Voltage
120V, 208V, 230V, 240V, 415V
120V, 208V, 230V, 240V
120V, 208V, 230V, 240V
120V, 208V, 230V, 240V
Output Plugs/Receptables
NEMA 5-15R
NEMA 5-20R
IEC-320 C13
IEC-320 C19
NEMA 5-15R
IEC-320 C13
NEMA 5-15R
IEC-320 C13
NEMA 5-15R
IEC-320 C13
Max Input Current
20A, 30A, 50A
13A, 15A, 20A
13A, 15A, 20A
13A, 15A
Phase
1Φ or 3Φ Power
1Φ Power
1Φ Power
1Φ Power
Transformer
240V input to 120V output option available
No
No
No

Networking Protocols and Software Management

SynLink SP
netBooter DX
netBooter DU
netBooter B
HTTP
Yes
Yes
Yes
Yes
HTTPS
Yes
Pre-installed or self-provided cert
Yes
Pre-installed or self-provided cert
Yes
Pre-installed cert only
No
DHCP
Yes
Yes
Yes
Yes
SMTP
Yes
Yes
Yes
Yes
Unencrypted basic SMTP
Telnet
Yes
Yes
Yes
Yes
SSH
Yes
Yes
No
No
Encryption
TLS v1.2
TLS v1.2
TLS v1.2
No
SNMP
SNMP v1, v2, v3
SNMP v1, v2, v3
SNMP v1, v2
No
Syslog
Yes
No
No
No
LDAP/Radius
Yes
Yes
No
No
IPv6
Yes
Yes
No
No
Synaccess Central Management Portal
Yes
Yes
No
No
Synaccess Desktop App
Yes
Yes
No
No
Local API
Yes, HTTP(s) RESTful
Yes, HTTP(s) RESTful
Yes, HTTP(s)
Yes, HTTP
3rd Party Integrations
Yes
Yes
No
No

Automation

SynLink SP
netBooter DX
netBooter DU
netBooter B
AutoPing / Reboot
Yes
Yes
Yes
Yes
Email Notifications
Yes
Yes
Yes
Yes
Unsecured SMTP
Webhooks
Yes
Yes
No
No
SNMP Trap
Yes
Yes
Yes
No
Scheduling
Yes
Hourly+Daily Scheduling
Yes
Hourly+Daily Scheduling
Yes
Daily Scheduling
Yes
Daily Scheduling
Customizable Event Triggers/Actions
Yes
Yes
No
No

Input Measurement

SynLink SP
netBooter DX
netBooter DU
netBooter B
Current RMS (A)
Yes
Yes
Yes
No
Line Frequency (Hz)
Yes
No
No
No
Voltage RMS (V)
Yes
No
No
No
Active Power (W)
Yes
No
No
No
Apparent Power (VA)
Yes
No
No
No
Power Factor
Yes
No
No
No
Energy Consumption (kWh)
Yes
No
No
No

Output Measurement

SynLink SP
netBooter DX
netBooter DU
netBooter B
Current RMS (A)
Yes
No
No
No
Active Power (W)
Yes
No
No
No

Advanced Features and Add-Ons

SynLink SP
netBooter DX
netBooter DU
netBooter B
Environment Sensors
Optional (Temp & Humidity)
Optional (Temp & Humidity)
Optional (Temp)
No
I/O Hub
Digital Inputs, Relay Outputs
Optional
No
No
No
Secondary Ethernet Port
Network Redundancy or Passthrough
Yes
with optional USB Ethernet adapter
Coming Soon
with optional USB Ethernet adapter
No
No
WiFi
Optional
No
No
No
Serial Console Server
Multiple Serial Devices
Single Serial Device
No
No
Mass Firmware Upgrades
Yes
Yes
No
No
Mass Configuration
Yes
Yes
No
No
Relay Health Sensor & Monitor
Yes
No
No
No
Circuit Breaker Protection
Optional
2x1 Pole CBs or 2x2 Pole CBs
No
No
No
Surge Protection
Optional
No
No
No
Automatic Transfer Switch (ATS)
Optional
No
No
No
Embedded 4G/LTE Modem (OOB Access)
Optional
No
No
No
Embedded 4G/LTE Modem (Passthrough)
Optional
No
No
No
Multi-Inlet Inputs
Optional (1U/2U)
No
Optional (1U/2U)
No
Transformer 240V input to 120V output
Optional
No
No
No
Leak Detection and Valve Control HUB
Optional
No
No
No